System
8.4 SYSTEM - "Service display"
Cylindrical grinding
Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
135
Error log
Error log display.
Figure 8-33 Dialog box, error log
All messages with the associated error information, where an error occurred when
processing them, are saved in the error log.
The error log can be deleted using the "reset" softkey.
The dialog box is closed by pressing "Back".
Note
The error log can be used for analysis when the information line "Processing error MSG
command occurred" is output.
Example of programming using the "MSG" command
For SINUMERIK 802D sl, messages programmed in the NC program are displayed in the
alarm display as standard.
Table 8- 3
Activating/deleting messages
N10 MSG ("Roughing the contour")
; The text "Roughing the contour"
is displayed in the alarm display
N20 X… Y… N …
N…
N90 MSG ()
; Delete message from the alarm
display