8.4 SYSTEM - "Service display"
Cylindrical grinding
134
Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
Settings to output in a file
Settings for the file storage location.
Figure 8-32 Dialog box, file settings
Sending messages to the selected file is activated or deactivated using the "Send to file"
checkbox. When the interface is deactivated, messages are not output and the information
line "Processing error MSG command occurred".
A path, the file name and the max. size of the file can be selected.
Drive D (customer CF card), F: (USB drive) and the drive connected per RCS connection
can be selected in the "Path" input field.
10kByte, 100kByte and 1MByte can be selected as max. file size. When the max. size is
reached, the file is written as ring buffer, i.e. at the beginning, as many lines are deleted line-
by-line as is required by the new message at the end of the file.
Here, when sending to a file, it can be defined as to which messages are sent for which
events:
●
Programmed messages from the part program
●
An alarm has occurred
The settings are saved and the dialog box exited by pressing the "OK" softkey.
The dialog box is exited without saving by pressing "Cancel".