Automatic mode
6.9 Execute from external
Cylindrical grinding
Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
97
4.
Programming device/PC:
–
Activate the drive/directory for network operation.
5.
Programming device/PC:
–
Establish an Ethernet connection to the control.
6.
Control: (see "Connecting / disconnecting a network drive")
–
Connect to the directory activated on the programming device/PC using the following
dialog:
Operating area <SYSTEM> > "Service Display" > "Service Control" > "Service
Network" > > "Connect" > "RCS Network" (Select a free drive of the control > Enter
the server name and and activated directory of the programming device/PC, for
example: "\\123.456.789.0\External Program")
Operating sequences for external execution via network
Select the <AUTOMATIC> mode key .
Press the <PROGRAM MANAGER> key on the machine control panel.
Press "RCS connect."".
You go to the directories of the PG/PC.
Place the cursor bar on the desired program.
Press "Ext. execution".
The program is transferred into the buffer memory and selected and displayed in the
program selection automatically.
Press the <NC START> key.
Machining starts. The program is reloaded continuously.
At the end of the program or in case of <RESET>, the program is automatically removed
from the control system.
Note
The program can only be executed. Program correction is not possible at the control.