Display
Example
Meaning
Remarks
oCxx
Selected connection macro
-
oAxx
Selected application macro
-
Cxxxx
Selected connection macro and
application macro
As described in the example, "01" represents
"C01", while "00" represents "A00".
Pxxxx
Parameter no. (Settable parameter)
P.xxxx
Parameter no. (Settable parameter)
This kind of parameters with a dot is only available
in quick motor data setting mode.
(For details, see "Notice" in Section 6.2.2.3)
rxxxx
Parameter no. (Read-only parameter)
Fxxxx
Fault code (in case of a single fault)
x.Fxxx
Fault code of the 1st fault (in case of
multiple faults)
The inverter can display up to 4 recently occurred
faults in turn.
Fault code of the 2nd fault (in case of
multiple faults)
Axxxx
Alarm code (in case of a single alarm)
x.Axxx
Alarm code of the 1st alarm (in case of
multiple alarms)
The inverter can display up to 4 recently occurred
alarms in turn.
Alarm code of the 2nd alarm (in case
of multiple alarms)
Err- -
Value setting impossible
- - - - -
- - - - -
Error parameter editing
It's a warning indicating that what you're trying to
edit is a read-only parameter and such editing is
not allowed.
xxx. xx
Parameter value, positive
Display a positive value of 5 digits at most.
-xxx.xx
Parameter value, negative
Display a negative value of 5 digits at most.
inxxx
Indexed parameter
The figure after "in" indicates the number of
indices. For example, "In013" means that this
indexed parameter has 13 indices.
bxxxx
See figure
below
Binary parameter
Meaning of each segment bit is described in
individual parameters concerned.
7 6
5 4
3 2
1 0
15
Segment-bit
Segment-bit
14 13 12
11 10
9 8
Figure 6-13 Binary parameter display
Commissioning
6.3 Operator panel overview
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
61