Mounting the operator panel to cabinet door
The inverter has a removable operator panel. If necessary, you can remove the operator panel
from the inverter and mount it to the cabinet door. (See topic "Mounting the operator panel to
cabinet door (Page 31)" for details.)
5.1.4
Mounting the operator panel to cabinet door
Mounting dimensions for door-mounted operator panel
You can detach the operator from inverter body unit and mount it to the cabinet door. This
provides you with the possibility of remote operator panel operation.
66.9
36.6
35
17
91
30
97
81.7
3.
7
4- 3.5
&XWRXW
DUHD
&DLQHWGRRU
Figure 5-10 Mounting dimensions (outline dime drill pa cut-out dimensions)
Table 5-4
Torques for fixing the operator panel to cabinet door
Holes to be drilled
in cabinet door
Fixing method
Tightening torque
(Nm)
4
4 x M3 preassembled screw and washer assemblies
(screw length: 12 mm)
0.8
NOTICE
If the screw is damaged during mounting, you can select similar M3 preassembled screws
and assemblies instead. But, make sure the screw length is between 12 mm and 18 mm.
Installation
5.1 Mechanical installation
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
31