Par.
No.
Name
Range
Unit
Default value
P1133 Ramp-down final
rounding time
0.00 - 40.00
s
0.00
0.00
0.00
0.00
0.00
0.00
P1080 Min. frequency
0.00 - 300.00
Hz
0.00
20.00
0.00
0.00
5.00
0.00
P1082 Max. frequency
0.00 - 300.00
Hz
50.00
50.00
50.00
50.00
50.00
50.00
P1300 Control mode
0 - 2
--
0
2
0
0
0
0
P1310 Continuous boost
0.0 - 250.0
%
50.0
0.0
50.0
0.0
50.0
50.0
P1311 Acceleration boost
0.0 - 250.0
%
0.0
0.0
0.0
50.0
0.0
0.0
P1312 Starting boost
0.0 - 250.0
%
0.0
0.0
0.0
0.0
0.0
0.0
P1240 Configuration of Vdc
controller
0 - 1
--
1
1
1
1
1
1
P1243 Dynamic factor of Vdc-
max
10 - 200
%
100
100
100
100
100
100
P1230 Enable DC braking
0:0 - 4,000:0
--
0:0
0:0
0:0
0:0
0:0
0:0
P1232 DC braking current
0 - 250
%
0
0
0
0
0
0
P1233 Duration of DC braking
0 - 250
s
0
0
0
0
0
0
P1200 Flying start
0 - 6
--
0
1
0
0
0
0
P1202 Motor-current: Flying start 10 - 200
%
100
100
100
100
100
100
P1203 Search rate: Flying start
10 - 200
%
100
100
100
100
100
100
P1210 Automatic restart
0 - 6
--
1
2
1
1
1
1
P0640 Motor overload factor [%] 10.0 - 400.0
%
150.0
150.0
150.0
150.0
150.0
150.0
P1110 Inhibit negative setpoint
0.0 - 2036.F
--
0
1
1
0
0
0
Commissioning