Option
Variant
MLFB (order number)
Door mounting components
The door mounting components include:
● Connecting cable, 3-meter long (1 piece)
● Production Information Sheet (1 piece)
● M3 preassembled screw and washer assemblies
(4 pieces)
-
6SL3256-0VP00-0VA0
To: inverter body unit
To: door-mounted operator panel
Connecting cable (inverter body unit to operator panel)
Choke
4)
Line commutating choke: A line commutating choke is
required to smooth spike pulses in power voltage, or
voltage sags generated during the phase change of a
bridge rectifier circuit; besides, a line commutating
choke can also used to lower harmonic interference to
inverter and power supply. If power impedance < 1%,
a line commutating choke is a must to reduce current
spikes.
Output choke: An output choke is necessary for
lowering varying rate of capacity current and voltage
(dv/dt) if the length of motor cable is longer than 50m
(shielded) or 100m (unshielded). For the detailed
information about the length of motor cable, please
refer to Technical data (Page 115)
Frame size
Rated out
put power
Line commutating
choke
Output choke
Frame Size A 0.55 kW
6SE6400-3CC00-
2AD3
(6SE6400-3CR00-
2AD3)
6SE6400-3TC0
0-4AD2
0.75 kW
6SE6400-3CC00-
4AD3
(6SE6400-3CR00-
4AD3)
1.1 kW
1.5 kW
6SE6400-3CC00-
6AD3
(6SE6400-3CR00-
6AD3)
Frame Size B 2.2 kW
6SE6400-3CC01-
0BD3
(6SE6400-3CR01-
0BD3)
6SE6400-3TC0
1-0BD3
3.0 kW
4.0 kW
6SE6400-3CC01-
4BD3
(6SE6400-3CR01-
4BD3)
Frame Size C 5.5 kW
6SE6400-3CC02-
2CD3
(6SE6400-3CR02-
2CD3)
6SE6400-3TC0
3-2CD3
7.5 kW
11 kW
6SE6400-3CC03-
5CD3
(6SE6400-3CR03-
5CD3)
Framze Size
D
15 kW
18.5 kW
6SE6400-3CC04-
4DD0
(6SE6400-3CR04-
4DD0)
6SE6400-3TC0
5-4DD0
22 kW
6SE6400-3TC0
3-8DD0
Operating Instructions
5)
English version
-
2)
The mounting kit consists of two mating parts. You can well engage both parts when installing.
3)
Only used for Frame Size D
4)
An order number without a bracket indicates that this choke is manufactured by a non-Chinese company, while an order
number with a bracket indicates that this choke is supplied by a local Chinese company. You can make your selection
according to your own needs.
Identification
SINAMICS V10
18
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)