Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
219
2. Example
Table 7- 23 Traversing blocks
Ind. No. Job
Par. Mode
s
v
a
-a
Advance
1
1
POSITIONING
0
RELATIVE
10000 2000 100
100
CONTINUE EXTERNAL
ALARM
2
2
POSITIONING
0
RELATIVE
10000 5000 100
100
CONTINUE EXTERNAL
ALARM
3
3
POSITIONING
0
ABSOLUTE
0
5000 100
100
END
The converter only goes to the next traversing block for the 0
→
1 change of the "External
block selection" signal.
Figure 7-45 Positioning an axis using traversing blocks