Advanced commissioning
7.5 Motor control
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
155
Parameter
Parameter
Explanation
p3820
…
p2839
Intermediate points of the friction characteristic [rpm; Nm]
r3840
Friction characteristic status word
.00 1 signal: Friction characteristic OK
.01 1 signal: Determination of the friction characteristic is active
.02 1 signal: Determination of the friction characteristic is complete
.03 1 signal: Determination of the friction characteristic has been aborted
.08 1 signal: Friction characteristic positive direction
r3841
Friction characteristic, output [Nm]
p3842
Activate friction characteristic
0: Friction characteristic deactivated
1: Friction characteristic activated
p3845
Activate friction characteristic plot (factory setting: 0)
0: Friction characteristic plot deactivated
1: Friction characteristic plot activated, both directions
2: Friction characteristic plot activated, positive direction
3: Friction characteristic plot activated, negative direction
p3846
Friction characteristic plot ramp-up/ramp-down time (factory setting: 10 s)
Ramp-up/ramp-down time for automatic plotting of the friction characteristic.
p3847
Friction characteristic plot warm-up period (factory setting: 0 s)
At the start of automatic plotting, the inverter accelerates the motor up to the speed =
p3829 und keeps the speed constant for this time.
You will find more information in the List Manual.