Functions
5.4 Setpoint sources
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.
99
5.4.4
Using the fixed frequency as a setpoint source
Frequency setpoint via fixed frequency (P1000 = 3)
The fixed frequencies are defined using parameters P1001 to P1004 and can be assigned to
the corresponding digital inputs using P1020 to P1023.
Parameter
Description
P1016 = 1
Fixed frequency mode,
defines the procedure
for selecting fixed
frequencies.
1: Direct selection
(factory setting)
2: Binary-coded
selection
P1001 = 0
Fixed frequency 1 (FF1)
(FF values in Hz)
P1002 = 5
Fixed frequency 2
((FF2)
P1003 = 10
Fixed frequency 3 (FF3)
P1004 = 15
Fixed frequency 4 (FF4)
P1020 = 722.3 FF1 selection using DI3
P1021 = 722.4 FF2 selection using DI4
P1022 = 722.5 FF3 selection using DI5
P1023 = 722.6 FF4 selection using DI6
The fixed frequency can be selected using four digital
inputs (factory setting: DI3 … DI6) and combined (e.g.
summed). The factory settings support the following
additional combinations:
3G]
3G]
3G]
3G]
33
33
33
33
33
333
333
333
3333
',3
',3
',3
',3
',',
',',
',',
',',
',',
',',',
',',',
',',',
',',',',
)L[HG)UHTXHQF\
VHOHFWHGYLD
))3DU
))
>+]@
Additional information about binary coded selection of the fixed frequencies (P1016 = 2) is
provided in function chart 3210 of the List Manual.