Commissioning
4.3 Preparing commissioning
Frequency inverter
48
Operating Instructions, 08.10. 2008, t.b.d.
4.3
Preparing commissioning
Prerequisites: before you start
Before you start parameterization, you should clarify the following issues about
commissioning your application.
Are the factory settings sufficient for your application?
Check which factory settings can be used and which need to be changed (see Section
'Commissioning with factory settings'). When doing so, you may find that you only need to
change just a few parameters.
Which motor are you using? [P0300]
●
A synchronous or induction motor?
The SINAMICS frequency inverters are preset in the factory for applications using 4-pole
three-phase induction motors that correspond to the performance data of the frequency
inverter.
Motor data / data on the motor rating plate
If you use the STARTER software and a SIEMENS motor, you only have to specify the
Order No. In all other cases, you must read-off the data from the motor rating plate and enter
into the appropriate parameters.
P0307
3~Mot
1LA7130-4AA10
EN 60034
Cos
ϕ
0.81
50 Hz
1455/min
5.5kW
19.7/11.A
230/400 V
∆/Υ
Cos
ϕ
0.82
60 Hz
6.5kW
460 V
10.9 A
1755/min
No UD 0013509-0090-0031 TICI F 1325 IP 55 IM B3
Υ
440-480
11.1-11.3 A
45kg
∆/Υ
220-240/380-420 V
19.7-20.6/11.4-11.9 A
P0311
P0308
P0304
P0305
P0310
95.75%
P0309