
Functions
5.11 Operation in fieldbus systems
Frequency inverter
182
Operating Instructions, 08.10. 2008, t.b.d.
Rules for the parameter range
The bit for selecting the parameter page functions as follows:
When it is set to 1, an offset of 2000 is applied in the converter to the parameter number
(PNU) transferred in the parameter channel request before the data is transferred.
,1'
D G F E I
H
Figure 5-33 IND page index (acyclic)
,1'
D G F E I
H
Figure 5-34 IND page index (cyclic)
Table 5- 63 Regulations for setting the PNU
Page index
Bit
Parameter range
a
d
c
b
f
e
9
8
Hex value
+ PNU
0000 … 1999
0
0
0
0
0
0
0
0
0x00
0 – 7CF
2000 … 3999
1
0
0
0
0
0
0
0
0x80
0 – 7CF
4000 … 5999
0
0
0
1
0
0
0
0
0x10
0 – 7CF
6000 … 7999
1
0
0
1
0
0
0
0
0x90
0 – 7CF
8000 … 9999
0
0
1
0
0
0
0
0
0x20
0 – 7CF
…
…
…
…
…
…
…
… …
…
…
32.000 … 33.999
0
0
0
0
0
1
0
0
0x04
0 – 7CF
…
…
…
…
…
…
…
… …
…
…
64.000 … 65.999
0
0
0
0
1
0
0
0
0x08
0 – 7CF
Table 5- 64 Sample coding of a parameter number in PKE and IND for P8820, index 16
PKE
IND
decimal
xx
820
32
16
hex
xx
334
20
10