Description
1.2 System components
SIMOTION D4x5-2
18
Manual, 02/2012
Ethernet
The control unit can communicate with the following components via the Ethernet interfaces
or be embedded in an automation environment:
Table 1- 4
Components on the Ethernet
Component
Function
Programming device (PG/PC)
... configures, parameterizes, programs, and tests with the
"SIMOTION SCOUT" engineering system (ES)
Master computer
... communicates with other devices via UDP, TCP/IP
SIMATIC HMI device
... is used for operating and monitoring functions. This is not an
essential requirement for the operation of a control unit.
PROFINET IO
The D4x5-2 DP/PN can communicate with the following components via the onboard
PROFINET IO interface or via the Ethernet communication board (CBE30-2).
Table 1- 5
Components on the PROFINET IO
Component
Function
Programming device (PG/PC)
... configures, sets parameters, programs, and tests using the
"SIMOTION SCOUT" Engineering System (ES).
SIMATIC HMI device
... is used for operating and monitoring functions. This is not an
essential requirement for the operation of a control unit.
Other controllers (e.g.
SIMOTION or SIMATIC)
... e.g. higher-level controller (plant controller); modular machine
concepts with multiple controllers, distributed across individual
machine modules.
Master computer
... communicates with other devices via UDP, TCP/IP.
Distributed I/O systems
TMC
Multi-channel, fast and isochronous I/O for mechanical engineering
with PROFINET IO connection in a rugged SINAMICS S120
booksize compact format; direct connection of the I/O channels on
the module or separately via wiring modules.
SIMATIC ET 200M
Modular I/O system for control cabinet installation and high
channel densities.
SIMATIC ET 200S
Finely scalable I/O system for control cabinet configuration and
particularly time-critical applications; including motor starters,
safety technology and individual grouping of load groups.
SIMATIC ET 200pro
Modular I/O system with IP65/67 degree of protection for machine-
related applications with no control cabinet; with features such as
compact designs, integrated PROFIsafe safety technology,
PROFINET IO connection and live module replacement.
SIMATIC ET 200eco PN
Compact block I/O with IP65/66/67 degree of protection for
cabinet-free usage in machines with M12 connection method. Very
rugged and resistant encapsulated metal enclosure.
Summary of Contents for SIMOTION TB30
Page 10: ...Table of contents SIMOTION D4x5 2 10 Manual 02 2012 ...
Page 36: ...Description 1 9 CompactFlash card SIMOTION D4x5 2 36 Manual 02 2012 ...
Page 46: ...Operator control hardware 2 3 7 segment and LED displays SIMOTION D4x5 2 46 Manual 02 2012 ...
Page 72: ...Interfaces 3 10 USB interfaces SIMOTION D4x5 2 72 Manual 02 2012 ...
Page 134: ...Supplementary system components 6 11 DMC20 DRIVE CLiQ hub SIMOTION D4x5 2 134 Manual 02 2012 ...