Supplementary system components
6.5 CX32-2 controller extension
SIMOTION D4x5-2
Manual, 02/2012
123
6.5.2.6
Measuring sockets
Application
The T0, T1 and T2 measuring sockets are used to output analog signals. Any signal
interconnectable via SINAMICS can be output on any measuring socket of the CX32-2.
CAUTION
The measuring sockets should be used exclusively for servicing purposes.
The measurements may only be performed by appropriately trained specialists.
The measuring sockets are suited for multiple-spring wire connectors with a diameter of
2 mm.
6.5.3
Displays of the LEDs
Description
Table 6- 27 CX32-2 LEDs
LED
Description
RDY
Operating modes of the CX32-2
DP
Status of the communication connection between the D4x5-2 and the CX32-2
Additional references
Detailed information on the states of the status LEDs can be found in the
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, Section
Diagnostics.
6.5.4
Cause and rectification of faults
The following reference contains information about the cause of faults and how they can be
rectified:
●
SIMOTION D4x5-2 Commissioning and Hardware Installation Manual.