Technical data of the D4x5-2
4.5 Interfaces and performance features
SIMOTION D4x5-2
82
Manual, 02/2012
Communication
Table 4- 12 Interfaces
Data
SIMOTION D4x5-2 DP
SIMOTION D4x5-2 DP/PN
DRIVE-CLiQ interfaces
6 (D425-2 DP: 4)
6 (D425-2 DP/PN: 4)
Ethernet interfaces
3
2
PROFIBUS interfaces
1)
2
2
PROFINET interfaces
2)
---
Onboard:
1 interface with 3 ports
Optionally:
Second interface with 4 ports via
CBE30-2
1)
Supports PROFIBUS DP, isochronous, can be configured either as master or slave
2)
Supports PROFINET IO with IRT and RT, can be configured as PROFINET IO controller and/or
device
Address space
Table 4- 13 Address space
SIMOTION D4x5-2 DP
SIMOTION D4x5-2 DP/PN
Logical I/O address space
16 KB
16 KB
Physical I/O address space for each
interface, one each for inputs and
outputs
•
PROFIBUS
•
PROFINET
•
1 KB
1)
•
1 KB
1)
•
4 KB
1) 2)
Permanent process image for
BackgroundTask (I/O variables)
64 bytes
64 bytes
Additional configurable process image
for each cyclic task (I/O variables)
Yes
Yes
Address space for each PROFIBUS DP
station
244 bytes
244 bytes
Address space for each
SINAMICS Integrated/CX32-2
(PROFIBUS Integrated)
512 bytes
512 bytes
Address space for each PROFINET
device
---
1400 bytes
1)
When PROFIBUS and PROFINET are used, the total address space applies: All I/O are assigned
in the logical I/O address space. The maximum number of I/Os is limited by the number that can
be addressed using the logical I/O address space.
2)
A second PROFINET interface for the D4x5-2 DP/PN Control Units is optionally available for the
CBE30-2.
Summary of Contents for SIMOTION TB30
Page 10: ...Table of contents SIMOTION D4x5 2 10 Manual 02 2012 ...
Page 36: ...Description 1 9 CompactFlash card SIMOTION D4x5 2 36 Manual 02 2012 ...
Page 46: ...Operator control hardware 2 3 7 segment and LED displays SIMOTION D4x5 2 46 Manual 02 2012 ...
Page 72: ...Interfaces 3 10 USB interfaces SIMOTION D4x5 2 72 Manual 02 2012 ...
Page 134: ...Supplementary system components 6 11 DMC20 DRIVE CLiQ hub SIMOTION D4x5 2 134 Manual 02 2012 ...