S5-95F
Operations List
Oper-
ation
(STL)
Permissible
Operands
1 RLO depend.
2 RLO affected
3 RLO reloaded
1
2
3
Typical
Execution Time
in
µ
s
On-
Ext.
board
I/O
Function
L
DW
N
N
N
34
Load a data word of the current data block into ACCU 1:
byte n ACCU 1 (bits
8-15);
byte n
+
1 ACCU
1
(bits
0-7).
L
KB
N
N
N
4.8
Load a constant (1-byte number) into ACCU 1.
L
KS
N
N
N
4.8
Load a constant (2 characters in ASCII format) into
ACCU 1.
L
KF
N
N
N
4.8
Load a constant (fixed-point number) into ACCU 1.
L
KH
N
N
N
4.8
Load a constant (hexadecimal code) into ACCU 1.
L
KM
N
N
N
4.8
Load a constant (bit pattern) into ACCU 1.
L
KY
N
N
N
4.8
Load a constant (2-byte number) into ACCU 1.
L
KT
4,8
Load a constant (time in BCD) into ACCU 1.
L
KC
N
N
N
4,8
Load a time or count (in binary code) into ACCU 1.
Load Operations (cont.)
L
T0 to 63
T64 to 127
C
N
N
N
N
N
N
480
45
16
Load a time or count (in binary code) into ACCU 1.
LC
T0 to 63
T64 to 127
C
N
N
N
N
N
N
480
95
16
Load times or counts (in BCD) into ACCU 1.
T
IB
N
N
N
1.6
4
Transfer the contents of ACCU 1 to an input byte (into
the PII).
T
QB
N
N
N
1.6
4
Transfer the contents of ACCU 1 to an output byte (into
the PIQ).
T
IW
N
N
N
6
16
Transfer the contents of ACCU 1 to an input word (into
the PII):
ACCU 1 (bits
8-15) byte n;
ACCU 1 (bits 0-7) byte n+1.
T
QW
N
N
N
11.2
Transfer the contents of ACCU 1 to an input word (into
the PII):
ACCU 1 (bits
8-15) byte n;
ACCU 1 (bits 0-7) byte n+1.
Transfer Operations
for organization blocks (OB)
for program blocks (PB)
for function blocks (FB)
for sequence blocks (SB)
L
KT
N
N
N
4.8
Load a constant (time in BCD) into ACCU 1.
L
KC
N
N
N
4.8
Load a constant (count in BCD) into ACCU 1.
EWA 4NEB 812 6210-02
C-3