Checking
When the
motor is
running
At
standstill
The smooth running characteristics and machine running noise have not
deteriorated
X
The motor foundation has no cracks and indentations (*)
X
X
The machine is aligned within the permissible tolerance ranges
X
All the fixing bolts/screws for the mechanical and electrical connections have
been securely tightened
X
All the potential connections, grounding connections and shield supports are
correctly seated and properly bonded
X
The winding insulation resistances are sufficiently high
X
Any bearing insulation is fitted as shown on the plates and labels
X
The CABLES and insulating parts and components are in good condition
and there is no evidence of discoloring
X
(*) You can perform these checks while the motor is at standstill or, if required, while running.
NOTICE
Machine damage
When carrying out the inspection, if you detect any impermissible deviations from the normal
state, you must rectify them immediately. They may otherwise cause damage to the machine.
9.1.4
Servicing the roller bearings
When inspecting rolling-contact bearings, it is generally not necessary to dismantle the
machines. The motor only has to be dismantled if the bearings are to be replaced.
9.1.5
Bolt grade
Check that all the bolts for attaching the bearing shields, bearing cover, gland plates, and
terminal boxes are present and properly tightened. Replace damaged bolts with identical bolts
of a perfect quality.
Depending on the ambient temperature, only bolts with the bolt grade according to the following
table are permissible for motors without heating.
Table 9-3
Bolt grade BG071 to BG315
Type/size
Bolt grade for ambient temperature T
u
≥ -40 °C
-55 °C ≤ T
u
< -40 °C
Standard
Stainless steel bolts
Standard
071, 080, 090, 100, 112, 132,
160, 180, 200, 225, 250, 280, 315
8.8
A4-70
A4-70
180.B
8.8
A4-80
A4-80
Maintenance
9.1 Inspection and maintenance
LOHER CHEMSTAR 1PS5
Operating Instructions 03/2014
85
Summary of Contents for SIMATIC S5 1P 243
Page 2: ...11 03 2014 02 49 V4 00 ...
Page 12: ...Introduction LOHER CHEMSTAR 1PS5 12 Operating Instructions 03 2014 ...
Page 20: ...Safety notes 2 11 Ventilation LOHER CHEMSTAR 1PS5 20 Operating Instructions 03 2014 ...
Page 66: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS5 66 Operating Instructions 03 2014 ...
Page 124: ...Disposal 11 4 Disposal of components LOHER CHEMSTAR 1PS5 124 Operating Instructions 03 2014 ...
Page 136: ...Quality documents C 4 Data LOHER CHEMSTAR 1PS5 136 Operating Instructions 03 2014 ...
Page 140: ...Index LOHER CHEMSTAR 1PS5 140 Operating Instructions 03 2014 ...
Page 141: ...AC EC Declaration of Conformity U161 AB EC Declaration of Conformity U163 AA R No 20000h U165 ...