↓ Grinding noise
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults
Remedial measures
X
X
Changes in foundation
Establish the cause of the changes and eliminate them if necessary;
realign the machine.
(1)
Take any changes into account when warming up the machine.
8.9.4
Roller bearing faults
Note
Damage to roller bearings can be difficult to detect in some cases. If in doubt, replace the
bearing. Use other bearing designs only after consulting the manufacturer.
Table 8-3
Roller bearing faults
↓ Bearing overheats
↓ Bearing "whistles"
↓ Bearing "knocks"
Possible causes of faults
Remedial measures
X
High coupling pressure
Align the machine more accurately.
X
Belt tension too high
Reduce the drive belt tension.
X
Bearing contaminated
Clean the bearing or replace it. Check the seals.
X
High ambient temperature
Use a suitable high-temperature grease.
X
X
Insufficient lubrication
Grease the bearings as instructed.
X
X
Bearing canted
Properly install the bearing.
X
X
Insufficient bearing play
Only after consultation with the manufacturer: Fit a bearing with
greater play.
X Excessive bearing play
Only after consultation with the manufacturer: Fit a bearing with
lower play.
X
X
Bearing corroded
Replace the bearing. Check the seals.
X
Too much grease in bearing
Remove surplus grease.
X
Wrong grease in the bearing
Use the correct grease.
X Friction marks on raceway
Replace the bearing.
X Scoring (brinelling)
Replace the bearing. Avoid any vibration at standstill
Operation
8.9 Faults
LOHER CHEMSTAR 1PS5
Operating Instructions 03/2014
79
Summary of Contents for SIMATIC S5 1P 243
Page 2: ...11 03 2014 02 49 V4 00 ...
Page 12: ...Introduction LOHER CHEMSTAR 1PS5 12 Operating Instructions 03 2014 ...
Page 20: ...Safety notes 2 11 Ventilation LOHER CHEMSTAR 1PS5 20 Operating Instructions 03 2014 ...
Page 66: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS5 66 Operating Instructions 03 2014 ...
Page 124: ...Disposal 11 4 Disposal of components LOHER CHEMSTAR 1PS5 124 Operating Instructions 03 2014 ...
Page 136: ...Quality documents C 4 Data LOHER CHEMSTAR 1PS5 136 Operating Instructions 03 2014 ...
Page 140: ...Index LOHER CHEMSTAR 1PS5 140 Operating Instructions 03 2014 ...
Page 141: ...AC EC Declaration of Conformity U161 AB EC Declaration of Conformity U163 AA R No 20000h U165 ...