● Charge transfer limit:
– IIB: Limit value for the largest transferred charge < 30 nC
– IIC: Limit value for the largest transferred charge < 10 nC for group II motors (gas)
– III: Limit value for the largest transferred charge < 200 nC for group III motors (dust)
● Incapability, dangerous charge to be saved:
– IIB: Limit value for the maximum capacity ≤ 15 pF
– IIC: Limit value for the maximum capacity ≤ 5 pF for group II motors (gas)
– III: Limit value for the maximum capacity ≤ 10 pF for group III motors (dust)
9.2
Repair
When carrying out any work on the machine, observe the general safety instructions
(Page 13) and the specifications contained in EN 50110‑1 regarding safe operation on
electrical equipment.
Note
If the motor has to be transported, please observe the information and instructions in the
"Transport" section.
Note
Service Center
Please contact the Service Center, if you require support with servicing, maintenance or
repair.
Maintenance
9.2 Repair
LOHER CHEMSTAR 1PS5
Operating Instructions 03/2014
97
Summary of Contents for SIMATIC S5 1P 243
Page 2: ...11 03 2014 02 49 V4 00 ...
Page 12: ...Introduction LOHER CHEMSTAR 1PS5 12 Operating Instructions 03 2014 ...
Page 20: ...Safety notes 2 11 Ventilation LOHER CHEMSTAR 1PS5 20 Operating Instructions 03 2014 ...
Page 66: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS5 66 Operating Instructions 03 2014 ...
Page 124: ...Disposal 11 4 Disposal of components LOHER CHEMSTAR 1PS5 124 Operating Instructions 03 2014 ...
Page 136: ...Quality documents C 4 Data LOHER CHEMSTAR 1PS5 136 Operating Instructions 03 2014 ...
Page 140: ...Index LOHER CHEMSTAR 1PS5 140 Operating Instructions 03 2014 ...
Page 141: ...AC EC Declaration of Conformity U161 AB EC Declaration of Conformity U163 AA R No 20000h U165 ...