8.9.5
Faults at the external fan
The following table shows the possible causes of and remedial measures for faults on forced-
ventilated machines.
Table 8-4
Cooling system faults
↓ High temperature rise with load
Possible causes of faults
Remedial measures
X Wrong direction of rotation of the external fan Check the electrical connections to the external fan.
X External fan is not running
Check the external fan and its connections.
X Reduced air flow
Check the air ducts; clean the machine.
8.9.6
Cooling system faults (water jacket cooling)
The following table shows the possible causes of and remedial measures for faults on water-
cooled machines.
Table 8-5
Cooling system faults
↓ Overheating
↓ Water leaking
Possible causes of faults
Remedial measures
X
Reduced cooling
Check the cooling water flow, increase the amount of cooling water if
necessary.
X
Cooling water flow rate too low
Consult the manufacturer. If the specified cooling water quality is
observed, the cooling system is maintenance-free.
X
Inlet temperature too high
Set the correct upstream temperature.
X
Cooling water supply switched off
Switch on the cooling water supply.
X
Cooling water contains frost or anti-
corrosion additives
Use cooling water of the agreed quality.
X Leaks in the cooling system
Consult the manufacturer.
X Defective cooling water connection
Find the leak and seal it.
Operation
8.9 Faults
LOHER CHEMSTAR 1PS5
80
Operating Instructions 03/2014
Summary of Contents for SIMATIC S5 1P 243
Page 2: ...11 03 2014 02 49 V4 00 ...
Page 12: ...Introduction LOHER CHEMSTAR 1PS5 12 Operating Instructions 03 2014 ...
Page 20: ...Safety notes 2 11 Ventilation LOHER CHEMSTAR 1PS5 20 Operating Instructions 03 2014 ...
Page 66: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS5 66 Operating Instructions 03 2014 ...
Page 124: ...Disposal 11 4 Disposal of components LOHER CHEMSTAR 1PS5 124 Operating Instructions 03 2014 ...
Page 136: ...Quality documents C 4 Data LOHER CHEMSTAR 1PS5 136 Operating Instructions 03 2014 ...
Page 140: ...Index LOHER CHEMSTAR 1PS5 140 Operating Instructions 03 2014 ...
Page 141: ...AC EC Declaration of Conformity U161 AB EC Declaration of Conformity U163 AA R No 20000h U165 ...