Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
256
Configuration Manual, 10/2021, C79000-G8976-C475-03
Steps in configuration
Enabling blocking for an individual port
1.
Select the check box in the relevant row in table 2.
2.
To apply the changes, click the "Set Values" button.
Enabling blocking for all ports
1.
In the "Setting" drop-down list, select the "Enabled" entry.
2.
Click the "Copy to Table" button. The check box is enabled for all ports in table 2.
3.
To apply the changes, click the "Set Values" button.
4.5.10
Inter-VLAN Bridge (SC63x/SC64x)
4.5.10.1
Overview
Overview
You can create one bridge per device and add a maximum of six VLANs to the bridge.
Description
The page contains the following boxes:
•
Bridge-ID
Enter the bridge ID in the "Bridge-ID" text box. The Bridge-ID (a number between 1
and 255) can only be assigned once when creating a new data record and can then no
longer be changed. To make a change, the entire data record must be deleted and
created again.