![Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual Download Page 174](http://html.mh-extra.com/html/siemens/simatic-net-scalance-sc-600/simatic-net-scalance-sc-600_configuration-manual_383906174.webp)
Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
174
Configuration Manual, 10/2021, C79000-G8976-C475-03
•
MIB Tree
Select the Object Identifier (OID) of the MIB area that is to be used for the SNMPv3
view. The following options are possible:
–
iso
–
std
–
member-body
–
org
–
mgmt
–
private
–
snmpV2
The drop-down list only contains the OIDs that are usually used. If the configuration
of a specific OID that is not listed is necessary, you can configure this via the CLI with
the
snmp view
command. This OID is then also displayed in the WBM in the
overview table.
The table has the following columns:
•
Select
Select the row you want to delete.
•
View Name
The name of the SNMPv3 view.
•
MIB Tree
The OID of the MIB area for the SNMPv3 view.
•
View Type
The available options are as follows:
–
Included
The MIB OID and its lower-level nodes are part of the SNMPv3 view. Access to the
corresponding MIB objects is possible.
–
Excluded
The MIB OID and its lower-level nodes are not part of the SNMPv3 view. Access to
the corresponding MIB objects is not possible.
Summary of Contents for SIMATIC NET SCALANCE SC-600