Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
295
Description
The page contains the following boxes:
•
RADIUS Authorization Mode
For the login authentication, the RADIUS authorization mode specifies how the rights
are assigned to the user with a successful authentication.
–
Conventional
In this mode the user is logged in with administrator rights if the server returns the
value "Administrative User" to the device for the attribute "Service Type". In all
other cases the user is logged in with read rights.
–
SiemensVSA
In this mode, the assignment of rights depends on whether and which group the
server returns for the user and whether or not there is an entry for the user in the
table "External User Accounts".
The table has the following columns:
•
Select
Select the row you want to delete.
•
RADIUS Server Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the RADIUS
server.
•
Server Port
Here, enter the input port on the RADIUS server. As default, input port 1812 is set.
The range of values is 1 to 65535.
•
Shared Secret
Enter your access ID here. The range of values is 1...128 characters
•
Shared Secret Conf.
Enter your access ID again as confirmation.
•
Max. Retrans.
Here, enter the maximum number of retries for an attempted request.
The initial connection attempt is repeated the number of times specified here before
another configured RADIUS server is queried or the login counts as having failed. As
default 3 retries are set, this means 4 connection attempts. The range of values is 1
to 5.