Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
296
Configuration Manual, 10/2021, C79000-G8976-C475-03
•
Primary Server
Using the options in the drop-down list, specify whether or not this server is the
primary server. You can select one of the options "yes" or "no".
•
Test
With this button, you can test whether or not the specified RADIUS server is available.
The test is performed once and not repeated cyclically.
•
Test Result
Shows whether or not the RADIUS server is available:
–
Not reachable
The IP address is not reachable.
The IP address is reachable, the RADIUS server is, however, not running.
–
Reachable, key not accepted
The IP address is reachable, the RADIUS server does not, however accept the
shared secret.
–
Reachable, key accepted
The IP address is reachable, the RADIUS server accepts the specified shared
secret.
Procedure
Entering a new server
1.
Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
–
RADIUS Server Address: 0.0.0.0
–
Server Port: 1812
–
Max. Retrans.: 3
–
Primary server: No
2.
In the relevant row, enter the following data in the input boxes:
–
RADIUS Server Address
–
Server Port
–
Shared Secret
–
Shared Secret Conf
–
Max. Retrans.: 3
–
Primary server: No
3.
If necessary check the reachability of the RADIUS server.
4.
Click the "Set Values" button.
Repeat this procedure for every server you want to enter.