Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
243
•
Edge Type
Specify the type of the "Edge Port". You have the following options:
–
"-"
Edge port is disabled. The port is treated as a "no Edge Port".
–
Admin
Select this option when there is always an end device on this port. Otherwise a
reconfiguration of the network will be triggered each time a connection is changed.
–
Auto
Select this option if you want a connected end device to be detected automatically
at this port. When the connection is established the first time, the port is treated
as a "no Edge Port".
–
Admin/Auto
Select these options if you operate a combination of both on this port. When the
connection is established the first time, the port is treated as an "Edge Port".
•
Edge
Shows the status of the port.
–
Enabled
An end device is connected to this port.
–
Disabled
There is a Spanning Tree or Rapid Spanning Tree device at this port.
With an end device, a switch can change over the port faster without taking into
account spanning tree frames. If a Spanning Tree frame is received despite this
setting, the port automatically changes to the "Disabled" setting.
•
P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port
that is set.
–
"-"
Point to point is calculated automatically. If the port is set to half duplex, a point-
to-point link is not assumed.
–
P.t.P.
Also with half duplex, a point-to-point link is assumed.
–
Shared Media
Even with a full duplex connection, a point-to-point link is not assumed.
Note
Point-to-point connection means a direct connection between two devices. A
shared media connection is, for example, a connection to a hub.