Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
121
•
Min. TLS version
Specify the minimum TLS version to be used.
•
Default Login Page
Specify the login page with which the WBM starts by default.
–
Firewall
Logging into the WBM page for dynamic firewall.
–
Configuration
Logging into the WBM.
•
SMTP Client
Enable or disable the SMTP client. You can configure other settings in "System >
SMTP Client".
•
Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System >
Syslog Client".
•
DCP Server
Specify whether the device can be accessed with DCP (Discovery and Configuration
Protocol):
–
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
–
Read/Write
With DCP, device parameters can be both read and modified.
–
Read Only
With DCP, device parameters can be read but cannot be modified.
•
Time
Select the setting from the drop-down list. The following settings are possible:
–
Manual
The system time is set manually. You can configure other settings in "System >
System Time > Manual Setting".
–
SIMATIC Time
The system time is set via a SIMATIC time source. You can configure other
settings in "System > System Time > SIMATIC Time Client".
–
SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
–
NTP Client
The system time is set via an NTP server. You can configure other settings in
"System > System Time > NTP Client".