Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
245
Description
Table 1 has the following columns:
•
All Ports
Shows that the settings are valid for all ports.
•
Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in
table 2 remains unchanged.
•
Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
•
Port
Shows the available ports.
•
Setting
Specify the LLDP functionality. The following options are available:
–
Rx
This port can only receive LLDP frames.
–
Tx
This port can only send LLDP frames.
–
Rx & Tx
This port can receive and send LLDP frames.
–
"-" (disabled)
This port can neither receive nor send LLDP frames.
Procedure
1.
Select the LLDP functionality of the port from the "Setting" drop-down list.
2.
Click the "Set Values" button.