Technical Specifications
7-15
ET 200X Distributed I/O Device
EWA 4NEB 780601602-06
Parameters
The following tables provide an overview of the parameters on the basic module
that can be set.
Table 7-6
Parameters of the BM 141 DI 8
DC 24V ECOFAST DIAG
Parameters
Range
Default
Area
S7 slave with
HWCONFIG
Standard slave
with DDB file
SIEM80D3.GSG
1
Standard slave
with DDB file
SI0380D3.GSG
1
affected
–––
–––
DP interrupt mode
DPV0/DPV1
DPV1
ET 200X
Diagnostic interrupt
Yes/no
Yes
ET 200X
Hardware interrupt
Yes/no
Yes
ET 200X
–––
Enhanced
diagnostics
2
–––
Yes/no
Yes
ET 200X
–––
–––
Startup when
expected/actual
config. differ
Yes/no
No
ET 200X
Diagnosis: no load voltage (S)
Yes/no
Yes
ET 200X
–––
–––
Module diagnosis
Yes/no
Yes
ET 200X
–––
–––
Module status
Yes/no
Yes
ET 200X
–––
–––
Channel-specific
diagnosis
Yes/no
Yes
ET 200X
1
As of basic module 6ES7 141-1BF40-0AB0, version 2
2
The length of the diagnostic frame is
32 bytes
Table 7-7
Parameters of the BM 141 DI 8
DC 24V ECOFAST DIAG for digital inputs
Parameters
Range
Default
Area affected
Input delay
1
0.5 ms/ 3 ms/ 15 ms/
20 ms
3 ms
Module
Diagnosis: short circuit
to M
Yes/no
No
Channel
Diagnosis: wire break
Yes/no
No
Channel
Diagnostic interrupt
Yes/no
No
Module
Hardware interrupt
Yes/no
No
Module
Hardware interrupt on
rising edge
2
Yes/no
No
Channel
Hardware interrupt on
falling edge
2
Yes/no
No
Channel
1
The input delay applies at ”0” to ”1” and at ”1” to ”0”.
2
These parameters can only be set if you enable the hardware interrupt parameter.
Summary of Contents for SIMATIC ET 200X
Page 8: ...Preface viii ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 20: ...Contents xx ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 40: ...Product Overview 1 20 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 58: ...Configuration Options 2 18 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 80: ...Installation 3 22 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 124: ...Configuration Options 2 18 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 328: ...Order Numbers A 10 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 348: ...Dimesioned Drawings and Pinouts C 18 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...
Page 362: ...Index Index 8 ET 200X Distributed I O Device EWA 4NEB 780601602 06 ...