![Siemens SIMATIC Distributed I/O System DP/ASi Link Manual Download Page 119](http://html.mh-extra.com/html/siemens/simatic-distributed-i-o-system-dp-asi-link/simatic-distributed-i-o-system-dp-asi-link_manual_382813119.webp)
C-3
Distributed I/O System DP/ASi Link
EWA 4NEB 710 6055-02b
Table C-1
Structure of the DP standard part in parameterization message, continued
Byte(s)
Meaning
Value
6
Group ID
You can place several DP slaves in one group with the
group ID.
1
Refer to Table C-3 for the watchdog time base
The station status defines the operating behavior of the DP/ASi link as a DP
slave. Its behavior towards other DP masters is determined; other aspects to
be determined are whether the SYNC and FREEZE modes and the watchdog
are being used.
Table C-2
Structure of station status in parameterization message
Bit(s)
Value
Meaning
0 to 2
000
Reserved
3
1
The watchdog for the PROFIBUS-DP is enabled in the
DP/ASi link.
4
1
The DP/ASi link can be operated in FREEZE mode.
5
1
The DP/ASi link can be operated in SYNC mode.
6, 7
00
The slave response time (T
SDR
) is modified. All other
parameters remain as they are.
01
The DP/ASi link is enabled for other PROFIBUS ma-
sters.
10
The DP/ASi link is disabled for other PROFIBUS ma-
sters. All parameters are applied; (exception:
T
SDR
+
0).
11
The DP/ASi link is enabled for other PROFIBUS ma-
sters.
Station status
Parameterization Message
Summary of Contents for SIMATIC Distributed I/O System DP/ASi Link
Page 6: ...vi Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b Preface ...
Page 18: ...1 6 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b Overview ...
Page 26: ...2 8 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b ASi Basics ...
Page 72: ...5 12 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b Configuring the DP ASi Link ...
Page 116: ...B 2 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b I O Code ...
Page 128: ...C 12 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b Parameterization Message ...
Page 148: ...Index 6 Distributed I O System DP ASi Link EWA 4NEB 710 6055 02b Index ...