5
5.12 Reading the Device Memory
122
Power Meter SICAM P 7KG7750/55, Manual
E50417-B1076-C340-A6, Edition 09.2013
Close
Click this button to terminate the dialog window
Read memory
.
Export
Click this button to save measured values or information as CSV file (Comma separated values)
or COMTRADE file (IEEE Standard Common Format for Transient Data Exchange). CSV files
can be read and processed, e.g., with Excel. COMTRADE files are used for exchanging mea-
sured data as documented in the IEEE Std C37.111-1999. The standardization includes both the
format for measuring files and the type of media used for the exchange of fault report, test or
simulation data of power supply systems.
Delete memory area
Click this button to delete the selected memory area in the device. Optionally, you can restart the
recording immediately or with the occurring of a parameterized trigger condition (mean values,
power values, and limit violations only).
5.12.2
Charts / Diagrams
Diagrams and charts are coupled: By moving the measuring cursor in the diagram, the corre-
sponding row in the chart is marked; by activating a row in the chart, the cursor in the diagram
moves to the corresponding timestamp (mean values, power values, and binary states only).
5.12.3
Diagrams
In diagrams, zooming, measuring and other functions are available. Click the right mouse button
in diagrams to activate the functions zoom, optimize, optimize x-axis, optimize y-axis, diagrams
(fade in or blind out diagram for measured value), signals (fade in or blind out diagram for mini-
mum, mean respectively maximum value) and copy diagrams in selectable size to the clipboard
(mean values, power values, binary states, and oscilloscope data only).
5.12.4
Timestamps
All timestamps are shown in regional normal time. This avoids time gaps or overlap in data (for
example, when summer time starts or ends).
5.12.5
Mean Value Record
Mean values are represented in a chart and in diagrams. In the chart, you can select between
minimum values, mean values and maximum values in headline. For each recorded mean value
(max. 8), one column in the chart and one diagram is shown. In the diagram, the mean value and
the tolerance area limited by minimum and maximum value are drawn.