Further notes
You disable this function with the
no fmp
command.
You display the status of this function and other information with the
show fmp stauts
and
show fmp limit
commands.
You define the limit values with the
fmp power-loss
and
fmp rx-power
commands.
12.2.2.2
no fmp
Description
With this command, you disable fiber monitoring.
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no fmp
Default: enabled
Result
Fiber monitoring is disabled.
Further notes
You enable this function with the
fmp
command.
You display the status of this function and other information with the and
show fmp limit
commands.
You define the limit values with the
fmp power-loss
and
fmp rx-power
commands.
12.2.2.3
fmp power-loss
Description
With this command, you specify the limit values for monitoring the power loss per port.
Diagnostics
12.2 FMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
570
Configuration Manual, 07/2017, C79000-G8976-C361-06