Result
The function of the button for restarting with factory settings is enabled.
Further notes
You disable this function with the
no panel-button control-factory-defaults
command.
4.3.1.2
no panel-button control-factory-defaults
Description
With this command, you disable the following function of the button:
● When the button is pressed for more than 12 seconds, there is a restart with the factory
settings.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no panel-button control-factory-defaults
Result
The function of the button for restarting with factory settings is enabled or disabled.
Further notes
You enable this function with the
panel-button control-factory-defaults
command.
4.3.1.3
panel-button control-faultmask
Description
With this command, you enable the following function of the button:
● If display mode D "fault mask" is displayed and the button is pressed for 5 - 12 seconds,
the fault mask is set.
This function corresponds to calling the
power
and
link
commands with the parameter.
Functions specific to SCALANCE
4.3 Panel button
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
135