4.3
Panel button
This section describes the commands relevant for working with the button.
You will find a detailed description of the function available using the button in the device
operating instructions.
Availability of the buttons
Depending on your IE switch, different buttons and functions are available, see section "System
functions hardware equipment (Page 25)".
4.3.1
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal
command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the
end
or
exit
command and are then in the
Privileged EXEC mode again.
4.3.1.1
panel-button control-factory-defaults
Description
With this command, you enable the following function of the button:
● When the button is pressed for more than 12 seconds, there is a restart with the factory
settings.
This function corresponds to calling the
restart
command with the parameter
factory
.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-factory-defaults
Functions specific to SCALANCE
4.3 Panel button
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
134