12.1.5
clear fault counter
Description
With this command you reset the counter that shows the number of faults since the last startup.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call the command without parameters:
clear fault counter
Result
The counter is set to "0".
Further notes
You shows the number of faults since the last startup with the
show fault counter
command.
12.1.6
fault report ack
Description
With this command, you acknowledge (delete) the messages of the "Cold/Warm start" event.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameter:
fault report ack <fault-state-id>
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
550