With this command, the clients are not enabled.
To enable the clients, use the
client config
command.
Note
Changing several message types or clients
With each command call, you can only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first select
the
all
option and then disable individual elements.
12.1.8.5
no event config
Note
The IE switch does not support all parameters, refer to the section "Features not supported
Description
With this command, you configure which of the various message types of the device will no
longer be stored or forwarded.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no event config
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|
faultstate-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-
change|dot1x-port-auth-state-change|poe- state-change|fmp-state-
change|env-data-change|linkcheck-change|cli-script-file-status|all}
{logtable|syslog|email|trap|faults
|
all}
The parameters have the following meaning:
Parameter
Description
cold-warmstart
Message if there is cold or warm restart
linkchange
Message when there is a status change on a physical interface
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
558
Configuration Manual, 07/2017, C79000-G8976-C361-06