Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is aRemote Monitoring alarm (RMON alarm)
● Message when there is a status change in the power supply
● Message when there is a status change in the redundancy manager (RM)
● Message when there is a status change on a standby connection
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message when there is a status change of the VRRP routers
● Message if there is a status change in the detection of network loops
● Message on status change of OSPF routers
● Message when there is a status change in the diagnostics data
● Message on status change of Link Check
● Message when an error was detected in the CLI script file:
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the Syslog server
● Sending an e-mail
● Sending an SNMP trap
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
event config
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|
faultstate-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
556
Configuration Manual, 07/2017, C79000-G8976-C361-06