Parameter
Description
authentication-
failure
Message if there is an incorrect login
rmon-alarm
Message when there is a RMON alarm
power-change
Message when there is a status change in the power supply
rm-state-change
Message when there is a status change in the redundancy manager
standby-state-
change
Message when there is a status change on a standby connection
faultstate-change
Message when there is a status change in the error monitoring
stp-change
Message when there is a change in the spanning tree
vrrp-state-change
Message on status change of VRRP routers
loopd-state-
change
Message if there is a status change in the detection of network loops
ospf-state-change
Message on status change of OSPF
dot1x-port-auth-
state-change
Message when there is a status change in the 802.1X authentication
poe-state-change
Message on status change of PoE
fmp-state-change
Message on status change of FMP
all
All messages
logtable
Client that processes the logbook entries
syslog
Client that sends the messages to the Syslog server
Client that sends the e-mails
trap
Client that sends the SNMP traps
faults
Error LED lights up. The setting is possible only for a cold or warm restart.
env-data-change
Message when there is a status change in the diagnostics data
linkcheck-change
Message on status change of Link Check
cli-script-file-
status
Message when an error was detected in the CLI script file:
all
All clients at once
Result
The setting deciding which messages of the device are not stored or forwarded is configured.
Further notes
You display the status of the events and the clients with the
show events config
command.
You configure which of the various message types of the device will be stored or forwarded
with the
event config
command.
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
559