Table 9-8
Switching properties
Device type
SCALANCE
Max. number of learna‐
ble addresses
Aging time
Switching technique
Latency
X204RNA
1023
30 seconds
"Store and forward"
15 - 135 µs
With HSR device:
Cut-through between
the ring ports HSR 1
and HSR 2.
With HSR device:
9 µs (regardless of
frame length)
X204RNA EEC
1023
30 seconds
"Store and forward"
15 - 135 µs
With HSR device:
Cut-through between
the ring ports HSR 1
and HSR 2.
With HSR device:
9 µs (regardless of
frame length)
Table 9-9
Permitted ambient conditions
Device type
SCALANCE
Operating temperature
Storage/transporta‐
tion temperature
Relative humidity
in operation
Operating altitude at max. xx°C
ambient temperature
X204RNA
-40 ℃ to +60 °C
-40 ℃ to +70 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204RNA EEC
-40 ℃ to +70 °C
(up to +85 °C / max. 16 h)
-40 ℃ to +70 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
Note
Note the orientation of the installed SCALANCE X204RNA and X204RNA EEC
If a SCALANCE X204RNA or X204RNA EEC is mounted on a vertical rail, an ambient
temperature of m40 °C is permitted.
Technical specifications
SCALANCE X-200RNA
Operating Instructions, 10/2016, C79000-G8976-C342-04
145
Summary of Contents for SCALANCE X-200RNA
Page 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...