Issue 04/02
9 Electro-Magnetic Compatibility
MICROMASTER 410 Operating Instructions
6SE6400-5EA00-0BP0
71
9.1.4
General cases of EMC performance
Three General cases of EMC performance are available as detailed below:
Case 1: General Industrial
Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3
for use in
Second Environment (Industrial)
and
Restricted Distribution
.
Table 9-1
Case 1 - General Industrial
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level group 1, class A
Conducted Emissions
EN 61800-3
Limits are weaker as EN55011, class A,
group 1
Immunity:
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3),
1 kV control (Level 3)
Radio Frequency Electromagnetic Field EN61000-4-3
26-1000 MHz, 10 V/m
Case 2: Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 61000-6-2.
Table 9-2
Case 2 - Filtered Industrial
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level group 1, class A
Conducted Emissions
EN 61800-3
Level are weaker as EN55011 class A,
group 1
Immunity:
Supply Voltage Distortion
EN 61000-2-4
Voltage Fluctuations, Dips, Unbalance,
Frequency Variations
EN 61000-2-1
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3),
2 kV control (Level 4)
Radio Frequency Electromagnetic
Field, amplitude modulated
EN 61000-4-3
80-1000 MHz, 10 V/m, 80% AM,
power and signal lines
Summary of Contents for micromaster 410
Page 1: ......
Page 5: ......
Page 10: ...Safety Instructions Issue 04 02 MICROMASTER 410 Operating Instructions 10 6SE6400 5EA00 0BP0 ...
Page 14: ...Table of Contents Issue 04 02 MICROMASTER 410 Operating Instructions 14 6SE6400 5EA00 0BP0 ...
Page 44: ...3 Commissioning Issue 04 02 MICROMASTER 410 Operating Instructions 44 6SE6400 5EA00 0BP0 ...
Page 56: ...5 System Parameters Issue 04 02 MICROMASTER 410 Operating Instructions 56 6SE6400 5EA00 0BP0 ...
Page 62: ...6 Troubleshooting Issue 04 02 MICROMASTER 410 Operating Instructions 62 6SE6400 5EA00 0BP0 ...
Page 68: ...8 Options Issue 04 02 MICROMASTER 410 Operating Instructions 68 6SE6400 5EA00 0BP0 ...
Page 74: ......
Page 80: ...Index Issue 04 02 MICROMASTER 410 Operating Instructions 80 6SE6400 5EA00 0BP0 ...
Page 82: ...MICROMASTER 410 Operating Instructions 82 6SE6400 5EA00 0BP0 ...
Page 84: ......