5 System Parameters
MICROMASTER 410 Operating Instructions
6SE6400-5EA00-0BP0
49
5 System
Parameters
5.1
Introduction to MICROMASTER System Parameters
The parameters can only be changed by using the Operator Panel (OP) or the
Serial Interface.
Parameters can be changed and set using the OP to adjust the desired properties
of the inverter, such as ramp times, minimum and maximum frequencies etc. The
parameter numbers selected and the setting of the parameter values are indicated
on the optional five-digit LCD display.
Ø
r
xxxx indicates a display parameter,
P
xxxx a setting parameter.
Ø
P0010 initiates “quick commissioning”.
Ø
The inverter will not run unless P0010 is set to 0 after it has been accessed.
This function is automatically performed if P3900 > 0.
Ø
P0004 acts as a filter, allowing access to parameters according to their
functionality.
Ø
If an attempt is made to change a parameter that cannot be changed in this
status, for example, cannot be changed whilst running or can only be changed
in quick commissioning, then
will be displayed.
Ø
Busy Message
In some cases - when changing parameter values - the display on the OP
shows
for maximum of five seconds. This means the inverter is busy
with tasks of higher priority.
5.1.1 Access
Levels
There are three access levels available to the user; Standard, Extended and
Expert. The level of access is set by parameter P0003. For most applications, the
Standard and Extended levels are sufficient.
The number of parameters that appear within each functional group (selected by
P0004) depends on the access level set in parameter P0003. For further details
regarding parameters, see the Parameter List.
Summary of Contents for micromaster 410
Page 1: ......
Page 5: ......
Page 10: ...Safety Instructions Issue 04 02 MICROMASTER 410 Operating Instructions 10 6SE6400 5EA00 0BP0 ...
Page 14: ...Table of Contents Issue 04 02 MICROMASTER 410 Operating Instructions 14 6SE6400 5EA00 0BP0 ...
Page 44: ...3 Commissioning Issue 04 02 MICROMASTER 410 Operating Instructions 44 6SE6400 5EA00 0BP0 ...
Page 56: ...5 System Parameters Issue 04 02 MICROMASTER 410 Operating Instructions 56 6SE6400 5EA00 0BP0 ...
Page 62: ...6 Troubleshooting Issue 04 02 MICROMASTER 410 Operating Instructions 62 6SE6400 5EA00 0BP0 ...
Page 68: ...8 Options Issue 04 02 MICROMASTER 410 Operating Instructions 68 6SE6400 5EA00 0BP0 ...
Page 74: ......
Page 80: ...Index Issue 04 02 MICROMASTER 410 Operating Instructions 80 6SE6400 5EA00 0BP0 ...
Page 82: ...MICROMASTER 410 Operating Instructions 82 6SE6400 5EA00 0BP0 ...
Page 84: ......