3 Commissioning
Issue 04/02
MICROMASTER 410 Operating Instructions
34
6SE6400-5EA00-0BP0
3.2.1
Commissioning without an Operator Panel
The inverter is supplied with an LED to indicate the operation state of the unit.
The inverter can be used with its default settings, for a number of applications. The
default settings are shown in Table 3-1.
The terminal layout is shown in the photograph of the Control Terminal
Connections on the inside of the back cover of this manual.
Table 3-1
Default settings for operation using the standard inverter
Terminals
Parameter Default
Default Operation
Digital Input 1
1
P0701 = ‘1’
ON/OFF1
Digital Input 2
2
P0702 = ‘12’
Reverse
Digital Input 3
3
P0703 = ‘9’
Fault Acknowledge
Warnings and faults states on the Inverter
The LED indicates the operating status of the inverter. The LED also indicate
various warnings or fault states. In section 6.1 on page 57 the inverter states,
indicated by the LED are explained.
3.2.2 Basic
operation
With the default settings of the inverter the following is possible:
Ø
Start and stopping the motor (DIN1 via external switch)
Ø
Reversing the motor (DIN2 via external switch)
Ø
Fault Acknowledgement (DIN3 via external switch)
Controlling the speed of the motor is accomplished by connecting the analog inputs
as shown in the Figure 3-3 (Switches and potentiometers are not supplied with the
inverter).
Figure 3-3
Basic operation
RS485
USS-protocol
Summary of Contents for micromaster 410
Page 1: ......
Page 5: ......
Page 10: ...Safety Instructions Issue 04 02 MICROMASTER 410 Operating Instructions 10 6SE6400 5EA00 0BP0 ...
Page 14: ...Table of Contents Issue 04 02 MICROMASTER 410 Operating Instructions 14 6SE6400 5EA00 0BP0 ...
Page 44: ...3 Commissioning Issue 04 02 MICROMASTER 410 Operating Instructions 44 6SE6400 5EA00 0BP0 ...
Page 56: ...5 System Parameters Issue 04 02 MICROMASTER 410 Operating Instructions 56 6SE6400 5EA00 0BP0 ...
Page 62: ...6 Troubleshooting Issue 04 02 MICROMASTER 410 Operating Instructions 62 6SE6400 5EA00 0BP0 ...
Page 68: ...8 Options Issue 04 02 MICROMASTER 410 Operating Instructions 68 6SE6400 5EA00 0BP0 ...
Page 74: ......
Page 80: ...Index Issue 04 02 MICROMASTER 410 Operating Instructions 80 6SE6400 5EA00 0BP0 ...
Page 82: ...MICROMASTER 410 Operating Instructions 82 6SE6400 5EA00 0BP0 ...
Page 84: ......