8.9.1
Content of the "Chart" tab
Evaluated data
The diagram evaluates the following data:
● Pipe spec, "Pipe spec limits" tab, "Class use limit" control group: "Rating" table
● Pipe spec elements, "Part attribute" tab, "Pressure/temperature dependency" control
group: Tables "T" and "P"
Display
X axis
Temperature
Y axis
Pressure
Legend
Top right-hand corner of the diagram:
● Red: The pipe spec
● Other colors: The pipe spec elements
No data available
When you click on the tab, even though a pressure/temperature rating has not been defined
for the pipe spec and the pipe spec elements, the message "Diagram empty" is displayed.
8.10
"Comments" tab
Procedure
Enter details that additionally document the pipe spec in the "Comments" field.
8.11
"Function" tab
Saves data for internal purposes.
Configuring pipe specs
8.11 "Function" tab
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA
109