Configuring Alarms, Areas, Home, Privacy Settings and Presets
10.3.1 Setting the North Position
Direction indicators permit you to understand the approximate pointing position of
the dome to an established reference point. This reference point is called “North”
and may correspond to magnetic north (if it is known) or some other landmark or
fixture. When the dome is initially installed, “North” defaults to a pre-defined
position (0° pan/tilt). You may program the “North” position to be any point along
the dome's pan axis (also called azimuth).
Programming
1. Select
Alarms/Areas/Home/Presets/PZ
from the Dome Configuration Menu.
2. Select
Set North Position
.
The Set North Position screen appears:
SET NORTH POSITION
PAN to new north position
ZOOM to mark north position
FOCUS quits w/o changing
Fig. 30
Set North position
3.
Point the dome to the new North position. When satisfied with the view, save
the setting, or cancel the change.
4. The
Alarms/Areas/Home/Presets/PZ
screen appears. Select Exit. The Dome
Configuration Menu appears.
112