Indoor Installation
7.
Connect housing and eyeball assembly to base (Fig. 11).
–
Align dimple on cap of dome with rib on mounting base.
–
Mate housing and eyeball assembly to base and turn it clockwise until you
hear a click.
LATCH
Fig. 11
Connecting housing and eyeball assembly to base
(cables and lanyard not shown)
8.
Wait a few seconds for dome to begin its homing routine. Homing routine
indicates that address was placed into dome memory and that dome is ready
for programming.
6.2
Connecting to a Mounting Base with I/O Board
This procedure explains how to connect the housing and eyeball assembly to the
optional mounting base with I/O board.
WARNING!
Ensure that AC power and electrical signals are off during wire connections!
CAUTION:
Detach and discard cable clamp if I/O board has one. If not removed, clamp can
damage 9-pin connector in housing and eyeball assembly when you attempt to
connect it to base.
1.
Set data communications jumper JW1. If data lines continue to another dome,
set JW1 across pins 1-2 (un-terminated). Otherwise, set JW1 across pins 2-3
(terminated).
2.
Connect video cable to BNC connector P8 on I/O board.
3.
Connect Siemens RS422/RS485, or SensorNet 485 data wires to
connector P1.
89