Indoor Installation
6 Indoor
Installation
This section explains how to connect the housing and eyeball assembly to a:
Standard mounting base
Mounting base with I/O board.
6.1
Connecting to the Standard Mounting Base
This procedure explains how to connect the housing and eyeball assembly to a
standard base.
WARNING!
Ensure that AC power and electrical signals are off during wire connections!
1.
Set dome address (Fig. 7).
Recessed at top of housing and eyeball assembly are three rotary address
switches. Address range is from 01 to 099.
Set switches from most significant bit (MSB) to least significant bit (LSB). For
example: For address 066, set SW3 to 0, SW2 to 6, and SW1 to 6.
0
9 0
9 0
9
MSB
LSB
SW3
SW1
SW2
Fig. 7
Setting the address switches