Page 97 of 106
TMS 5001
22. Insert P1 valve retaining ring.
23. Cleaning the retaining valves.
Do not apply grease at all on the components.
Check (visually) whether there are signs of damage in the flat end. If the non-return
valve is damaged, replace it.
24. Check (visually) whether the inner valve seat ring
(see arrow) is damaged.
If the ring is damaged, replace it.
25. Apply a fine layer of grease (Ref. OE 0101-020)
in the outer side of the “0” seat rings (see arrow).
26. Turn the unit upside down and insert the non-return valves of function valves P1 and P2.
The flat end must be oriented towards the ring seat, which will be inserted next.
27. Insert valve P1 in the ring seat:
Pick the ring by inserting the Seeger pliers in its lateral holes. Turn the ring from left to right and tighten it down
into the unit.