Once the lift adjustment process is over, adjust the lead in conveyor rollers. Use the preforms of the new
format or a gauge with the measure for the format intended.
1. Loosen the bolts marked in the picture, two on each end, and open or close the rollers DEPENDING
on the format intended.
2. Place the two preforms on each end and adjust the position of the rollers so that the body of the preform
passes through the two rollers and so that the preform wing prevents it from falling. Depending on the
dimensions of the preform wing, leave more or less space between the roller and the preform (“X”
measure).
3. Once the rollers have been adjusted, tighten the bolts marked in the picture. Repeat these steps for
each pair of rollers.