2.
Start measurement
Request: <STX>sMN LMCstartmeas<ETX>
Reply: <STX>sAN LMCstartmeas 0<ETX>
3.
Log out and start device
Request: <STX>sMN Run<ETX>
Reply: <STX>sAN Run 0<ETX>
4.
Request measurement status
NOTE
Query the status until status 7 (“measurement”) is achieved in the response.
Request: <STX>sRN STlms<ETX>
Reply: <STX>sRA STlms 7 0 8 00:00:00 8 01.0 1.06 0 0 0<ETX>
NOTE
If the status is less than 7, send request again.
5.
Starting output of measured values of a single scan
Request: <STX>sRN LMDscandata<ETX>
Reply: <STX>sRA LMDscandata<ETX>
If an error is present and reported in the response telegram: Depending on the type of
error, the device will either stop measurement mode or not.
Example of continuous output of measured values
1
2
3
Figure 27: Continuous output of measured values
1
Measured value query
2
Output measured-value telegrams
3
Command to stop the output
3