6.4.2
Connections of LMS511, LMS581 and LMS511 Heavy Duty
LMS511 Lite/PRO/Heavy Duty Outdoor, LMS581 PRO, LMS531 Lite/Pro: "Power” connection
Table 23: LMS511 Lite/PRO/Heavy Duty Outdoor, LMS581 PRO, LMS531 Lite/Pro: "Power” connection
Male/female connec‐
tor
Contact
Short form
Signal description
Wire colors connect‐
ing cable part no.
6036159
1.
1
4
3
5
2
Figure 41: M12 male
connector, 5-pin, A-
coded
1
V
S
Sensor supply voltage
Brown
2
V
S
heat.
Heating supply voltage
White
3
GND
Ground sensor
Blue
4
Reserved
Do not use!
–
5
GND heat.
Ground heating
Black
1.
Example values when using the specified connecting cable(s). Signal assignment and wire colors can vary when using other connecting
cables.
Required minimum voltage at flying leads for part no. 6036159: 20.3 V
LMS511 Lite/PRO/Heavy Duty Outdoor, LMS581 PRO and LMS531 Lite/PRO: “Ethernet” connection
Table 24: LMS511 Lite/PRO/Heavy Duty Outdoor, LMS581 PRO and LMS531 Lite/PRO: “Ethernet” connection
Male/female connector
Contact
Short form
Signal description
1
4
3
2
Figure 42: M12 female con‐
nector, 4-pin, D-coded
1
TX+
2
Rx+
R
3
TX–
Sender–
4
Rx–
Receiver–
LMS511 Lite Outdoor: “Data” connection
Table 25: LMS511 Lite Outdoor: Pin assignment of the “Data” connection
Male/female connector
Contact
Short form
Signal description
Wire colors connect‐
ing cable part no.
6036153
1.
1
7
2
6
3
4
5
8
Figure 43: M12 male connec‐
tor, 8-pin, A-coded
1
RD–/RxD
RS-422/RS-232 receiver
White
2
TD–/TxD
RS-422 / RS-232 sender
Brown
3
RD+
RS-422 receiver
Green
4
TD+
RS-422 sender
Yellow
5
GND RS
RS-422/RS-232 ground
Gray
6
Reserved
Do not use!
Pink
7
IN Sync
Synchronization input
Blue
8
GND IN Sync
Synchronization ground
Red
1.
Example values when using the specified connecting cable(s). Signal assignment and wire colors can vary when using other connecting
cables.
ELECTRICAL INSTALLATION
6
8013796/1ALS/2021-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
59