LMS500 Pro Indoor: “Power/Data/I/O” connection in system plug
Table 20: LMS500 Pro Indoor: Terminal assignment of the “Power/Data/I/O” connection
Male/female connector
Contact
Short form
Signal description
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Figure 40: 2 x terminal strip,
13-pin
01
V
S
Sensor supply voltage
02
GND
Ground sensor
03
OUT1
Digital output 1
04
OUT2
Digital output 2
05
OUT3
Digital output 3
06
IN1
Digital input 1
07
IN2
Digital input 2
08
GND IN1/2
Ground for digital inputs 1 and 2
09
GND IN3/4/IN Sync
Ground for digital inputs 3 and 4 / Input
Synchronization
10
IN3
Digital input 3
11
IN4/IN Sync
Digital input 4 / Synchronization input
12
OUT4
Digital output 4
13
OUT5
Digital output 5
14
V
S
OUT
Digital output supply voltage
15
GND V
S
OUT
Supply voltage ground of digital outputs
16
TD+
RS-422 sender
17
TD–/TxD
RS-422 / RS-232 sender
18
GND RS
RS-422/RS-232 ground
19
RD–/RxD
RS-422/RS-232 receiver
20
RD+
RS-422 receiver
21
RS shield
RS-422/RS-232 shielding
22
CAN shield
CAN bus shielding
23
CAN H
CAN bus HIGH
24
GND CAN
Ground CAN-BUS
25
CAN L
CAN bus LOW
26
OUT6/OUT Sync
Digital output 6 / Synchronization output
Yellow bypass switch at the system connection
By moving the bypass switch, you can select which pins provide the supply voltage for
the outputs or which pin provides the ground potential of the inputs.
NOTE
If the bypass switch is set as "bridge", a higher power is consumed via the supply cable
of the sensor (supply power for sensor and outputs).
ELECTRICAL INSTALLATION
6
8013796/1ALS/2021-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
57
Subject to change without notice